Product Details:
Body Material | Metal |
Brand | Danfoss, VACON, L&T, LS, LG, CG, FUJI, KEB, KIRLOSKAR, ABB, SIEMENS, ROCKWELL, ALLEN BRADLEY |
Output Power | 0.37 - 5200 kW |
Application | Refrigeration |
Input Supply Voltage | 220-690 VAC |
Input Frequency | 45 to 65 Hz |
Input Type | Analog Input |
Display | LED, Digital |
The VLT® Refrigeration Drive FC 103 is designed to help significantly reduce the lifecycle costs of your refrigeration systems. It offers efficiency- and reliability-enhancing features, integrated process control functions and a commissioning environment specially designed to meet the needs of refrigeration applications. It also features a setup Wizard which uses common refrigeration terms. This makes installation and commissioning easy and safe for refrigeration technicians and installers.
The continuous variable speed control provided by the VLT Refrigeration Drive makes intelligent capacity control possible. By creating stability while balancing the capacity to the actual load, system-wide coefficient of performance improves providing significant energy savings in a wide range of applications.
The drive contains all modules necessary for compliance with EMC standards. The integrated, scalable RFI filter minimizes electromagnetic interference, and the integral DC link chokes reduce harmonic distortion in the mains network. As these features are built in to the drive in the factory, cabinet space can be reduced. Efficient EMC mitigation also enables the use of cables with small cross sections which reduces installation costs.
Additional Information:
Product Details:
Brand | Danfoss |
Model Name/Number | LD 302 |
Supply Voltage | 380 - 400 V AC +-10% |
Supply frequency | 50/60 Hz +-5% |
Supply Phase | Three Phase |
Output voltage | 0 - 100% of supply voltage |
Output frequency | 0-590 Hz |
Ramp times | 0.01-3600 sec. |
The VLT® Lift Drive is designed to provide reliable operation and excellent ride comfort for a minimum of 2.1 million cycles when running at an ambient temperature of below 45°C. Ideal for new projects or for retrofits, it operates without motor contractors and can be quickly and easily commissioned in less than 10 minutes.
Designed for all motors, including asynchronous, induction, permanent magnet, copper rotor and direct online PM motors, the VLT Lift Drive is suitable for both traction and hydraulic lifts in open- or closed-loop systems.
The compact design and intelligent cooling concept means it easily fits even into small installation spaces. And a range of built-in features eliminates the need for extra components. Scalable RFI filters minimize electromagnetic interference, integrated DC chokes suppress harmonics while ensuring the drives meet relevant EMC standards, and step-up, step-down transformers are not required.
Supply voltages and power range
Product Details:
Brand | Danfoss |
Model Name/Number | FC 360 |
Input Phase | 3 - Phase |
Country of Origin | Made in India |
Voltage | 380-480 V. |
Power | 0.37 - 75 KW |
Phase | Three Phase |
Operating Temperature Range | -25 DegreeC to +50 DegreeC |
Built to last, this robust drive operates effectively and reliably even with the most demanding applications and in the most challenging environments.
VLT® AutomationDrive takes full advantage of all that the new digital age has to offer to ensure it completely fulfills the requirements of your applications and optimizes your processes throughout the entire lifecycle.
Its cutting-edge thermal design and unique back-channel cooling make VLT® AutomationDrive one of the most compact and cost-efficient drives in the market. And new intelligent maintenance features and a range of DrivePro® services proactively improve productivity, performance and uptime.
Product Details:
Brand | Danfoss |
Model Name/Number | FC 103 |
Output voltage | 0 - 100% of supply voltage |
Ramp times | 1 - 3600 sec. |
Output frequency | 0 - 590 Hz |
Voltage Level | 0 - 24 VDC |
Programmable relay outputs | 2 (240 VAC, 2 A and 400 VAC, 2 A) |
The VLT® Refrigeration Drive FC 103 is designed to help significantly reduce the lifecycle costs of your refrigeration systems. It offers efficiency- and reliability-enhancing features, integrated process control functions and a commissioning environment specially designed to meet the needs of refrigeration applications. It also features a setup Wizard which uses common refrigeration terms. This makes installation and commissioning easy and safe for refrigeration technicians and installers.
The continuous variable speed control provided by the VLT Refrigeration Drive makes intelligent capacity control possible. By creating stability while balancing the capacity to the actual load, system-wide coefficient of performance improves providing significant energy savings in a wide range of applications.
The drive contains all modules necessary for compliance with EMC standards. The integrated, scalable RFI filter minimizes electromagnetic interference, and the integral DC link chokes reduce harmonic distortion in the mains network. As these features are built in to the drive in the factory, cabinet space can be reduced. Efficient EMC mitigation also enables the use of cables with small cross sections which reduces installation costs.
Supply voltages and power range:
Product Details:
Motor Power (kW) | 0.37 - 22 kW |
Brand | Danfoss |
Display | Digital |
Motor RPM | 2880 RPM, 1440 RPM, 960 RPM |
Input Phase | Single & Three Phase |
Output Phase | Three Phase |
Condition | New |
The VLT® Lift Drive is designed to provide reliable operation and excellent ride comfort for a minimum of 2.1 million cycles when running at an ambient temperature of below 45°C. Ideal for new projects or for retrofits, it operates without motor contractors and can be quickly and easily commissioned in less than 10 minutes.
Designed for all motors, including asynchronous, induction, permanent magnet, copper rotor and direct online PM motors, the VLT Lift Drive is suitable for both traction and hydraulic lifts in open- or closed-loop systems.
The compact design and intelligent cooling concept means it easily fits even into small installation spaces. And a range of built-in features eliminates the need for extra components. Scalable RFI filters minimize electromagnetic interference, integrated DC chokes suppress harmonics while ensuring the drives meet relevant EMC standards, and step-up, step-down transformers are not required.
Product Details:
Brand | Danfoss |
Model Name/Number | FC 280 |
Voltage | 380-480 V |
Frequency | 50 Hz |
Phase | Three Phase |
Power | 0.37-22 kW |
Reach new levels of performance with the VLT® Midi Drive FC 280, the evolution of the popular VLT® 2800 drive. Profit from new savings with a wide range of features designed to make installing, using and maintaining the AC drive as simple and as easy as possible.
For precise and efficient motor control for machine builders in the food and beverage, material handling and processing industries, the VLT® Midi Drive is ideal. it is strong on control performance, functional safety and flexible fieldbus communication.
VLT® Midi Drive is designed for compatibility with the VLT® 2800. Its exterior dimensions, connectors, cable lengths and set-up software tools allow you to easily retrofit an established drive panel.
Supply voltages and power range:
Product Details:
Brand | Danfoss |
Model Name/Number | FC 301 / FC 302 |
Analogue Output Current Range | 0/4 - 20 mA |
Programmable analogue outputs | 1 |
Voltage level | 0 - 24 VDC |
Ramp times | 1 - 3600 sec. |
Built to last, this robust drive operates effectively and reliably even with the most demanding applications and in the most challenging environments.
VLT® AutomationDrive takes full advantage of all that the new digital age has to offer to ensure it completely fulfills the requirements of your applications and optimizes your processes throughout the entire lifecycle.
Its cutting-edge thermal design and unique back-channel cooling make VLT® AutomationDrive one of the most compact and cost-efficient drives in the market. And new intelligent maintenance features and a range of DrivePro® services proactively improve productivity, performance and up time.
Supply voltages and power range:
Low harmonic drive:
12-pulse drive:
High-precision positioning and synchronization with reduced costs and system complexity
To optimize performance, many applications across all industry sectors have a need for precise positioning and synchronization. These applications include:
To date, positioning and synchronization operations have been performed using servo drives. However, servo equipment is expensive; it is difficult to commission and requires additional cabling. And, as servo drives do not work with open loop control systems, there is a high failure rate. Many applications do not require the high dynamic performance offered by a servo drive. An alternative was to use an AC drive. But, until now, an additional internal or external module or an encoder on the motor was required.
Product Details:
Brand | Danfoss |
Input Voltage | 380-480 V |
Input Phase | 3 - Phase |
Model Name/Number | FC 102 |
Input Power | 1.1-1000 kW |
Low Harmonic Drive | 380-480 V - 160-710 kW |
Get even higher reliability and lower total cost of ownership (TCO) in your heating, ventilation and air-conditioning (HVAC) installations, with this unique VSD optimized for building automation systems.
More than ever, the extreme climates, inaccessible machine rooms and isolated outposts of our planet need the best process control there is for their HVAC installations. Your everyday critical functions and costly systems need it too, as they face ever-increasing competition and efficiency demands. Always with high performance in mind, the enhanced VLT® HVAC Drive gives you more room to maneuver. It confronts the issues and gives you rock-solid reliability. With rock-bottom lifecycle costs too.
Endorsed by the World Alliance for Efficient Solutions as a Solar Impulse Efficient Solution.
The 1000 Efficient Solutions comprise the very best the world has to offer in clean and profitable solutions to protect the environment. VLT® HVAC Drive achieved the top score of 4.0, assessed on the criteria of viability, deployability, and sustainability.
Supply voltages and power range:
Low harmonic drive:
12-pulse drive:
Product Details:
Brand | Danfoss |
Model Name/Number | FCP 106 |
Supply Voltage | 380 - 480 V +-10% |
Supply Frequency | 50/60 Hz |
Ambient temperature | 40 DegreeC (104 DegreeF) (24-hour average) |
Minimum ambient temperature during full-scale operation | -10 DegreeC (14 DegreeF) |
Minimum ambient temperature at reduced performance | -20 DegreeC (-4 DegreeF) |
Maximum ambient temperature at reduced performance | 50 DegreeC (122 DegreeF) |
For full flexibility in motor type, system design and energy efficiency, connect the standalone drive VLT® DriveMotor FCP 106 to your choice of induction motor or permanent magnet motor.
Installation of this low-voltage drive is simple due to the integrated cooling system and an individually adjustable motor adapter plate. Alternatively, mount the VLT® DriveMotor FCP 106 close to the motor using the wall mount adapter plate.
The need for cabinets and long motor cables are eliminated enabling you to save costs however your system design looks.
Built-in features for smooth and efficient pump, fan and conveyor operation make this drive easy to integrate and commission for these dedicated applications.
Supply voltages and power range:
Product Details:
Brand | Danfoss |
Model Name/Number | FCD 302 |
Supply voltage | 380 - 480 V +-10% |
Supply frequency | 50/60 Hz |
True Power Factor | 0.92 nominal at rated load |
Output voltage | 0 - 100% of supply |
Output frequency | 0 - 590 Hz,0 - 300 Hz (Flux mode) |
Ramp times | 0.01 - 3600 sec. |
Designed for simplicity and robustness, the VLT® Decentral Drive FCD 302 is a user-friendly product with high performance and a strong protection degree.
A decentral-drive solution eliminates the need for space-consuming control cabinets. And, with the drives placed near the motor, there is no need for long-screened motor cables.
With the VLT Decentral Drive FCD 302, all the options are built into the unit reducing the number of boxes to be mounted, and the connections and terminations in the installation. As a result, labor costs and the risks of failure are dramatically reduced.
Supply voltages and power range:
Product Details:
Minimum Order Quantity | 1 Piece |
Motor Power (kW) | 0.37 - 5200 kW |
Display | Digital |
Brand | DANFOSS |
Motor RPM | 960 RPM, 2880 RPM, 1440 RPM |
Input Phase | Single & Three Phase |
Output Phase | Three Phase |
Condition | New |
The VLT® AQUA Drive is designed to provide the highest level of performance of AC-motor-driven water and wastewater applications. Featuring a wide range of powerful standard features, which can be expanded with performance-improving options, the drive is equally suited to both new and retrofit projects.
The considerable daily load variation in water or wastewater treatment plants makes it economically feasible to introduce motor control on rotating equipment such as pumps and blowers. The new generation VLT AQUA Drive can realistically offer first-year cost savings of between 10–30% compared to traditional drive solutions. Its high lifetime availability and low energy consumption and maintenance costs provide you with the lowest cost of ownership.
The quick and user-friendly setup of water and pump settings reduces installation time ensuring a fast route to maximum energy efficiency and motor control. By collecting the most important parameters in one place, the risk of incorrect configuration is reduced significantly.
Additional Information:
Product Details:
Motor Power (kW) | 0.37 - 5200 kW |
Brand | Danfoss |
Display | Digital |
Motor RPM | 2880 RPM, 1440 RPM, 960 RPM |
Input Phase | Single & Three Phase |
Frequency | 50/60 Hz |
Output Phase | Three Phase |
Low Harmonic Drive improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives or it can be installed as a compact standalone solution at a point of common coupling to compensate for several loads simultaneously.
The active filter ensures optimal harmonic suppression independent of the number of loads and their individual load profile. In addition, it corrects the power factor and balances the phase load to provide optimal energy utilization.
Product Details:
Material | Mild Steel |
Usage/Application | Industrial |
Brand | Danfoss |
Frequency | 50 / 60 Hz |
Voltage | 380 - 480 V AC |
Current Range | 190 A,250 A,310 A,400 A |
Product Details:
Material | Mild Steel |
Phase | Three Phase |
Usage/Application | Industrial |
Frequency | 50 and 60 Hz |
Brand | Danfoss |
Line Voltage | 380 to 415 V AC |
Product Details:
Usage/Application | Sequence Controllers |
Voltage | 380 V |
Phase | Three Phase |
IP Rating | IP68 |
Type | Automatic |
Digit Display Size | Single Display |
Frequency | 50 Hz |
Product Details:
Power | 10-100 KW |
Brand | Danfoss |
Voltage | 220V,440V |
Phase | Three Phase |
Speed | 2000-6000 RPM |
Frequency | 50/60 Hz |
Model Name/Number | FCP 106 |
Color | Black |
Product Details:
Brand | Danfoss |
Voltage | 380-480 V |
Phase | Three Phase |
Power | 0.75-2.2 kW |
Frequency | 50/60 Hz |
Application | Industrial |
The VLT® OneGearDrive® is a highly efficient, permanent magnet, three-phase synchronous motor coupled with an optimized bevel gear box which helps to optimize plant productivity and reduce energy costs.
With only one motor type and three available gear ratios, the motor concept covers all typical versions of conveyor drives commonly used in the food and beverage industry. The reduced range of physical configurations reduces costs and simplifies spare-part storage. Uniform mechanical dimensions reduce engineering and installation time and costs.
The drive comes in two versions: Standard for use in dry and wet production areas and Hygienic for use in wet areas and environments with high cleaning intensity including aseptic and cleanroom production areas.
Features and benefits:
Product Details:
Brand | Danfoss |
Model | AAF 006 |
Voltage | 380-480 V |
Current | 190-400 A |
Frequency | 50/60 Hz |
Application | Industrial |
The VLT® Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives or it can be installed as a compact standalone solution at a point of common coupling to compensate for several loads simultaneously.
The active filter ensures optimal harmonic suppression independent of the number of loads and their individual load profile. In addition, it corrects the power factor and balances the phase load to provide optimal energy utilization.
Additional voltage ranges and filter currents are available on request.
Product Details:
Minimum Order Quantity | 1 Unit |
Cooling Method | Fan |
IP Rating | IP65 |
Automation Grade | Automatic |
Brand | Danfoss |
Usage/Application | Industrial |
Display | Digital |
Input Phase | Single & Three Phase |
Model Number | FC051 |
The VLT® Micro Drive FC 51 is small and yet powerful and built to last. Panel space can be saved and installation costs reduced thanks to its compact size and minimal commissioning requirements.
Despite its compact size and easy commissioning, the VLT Micro Drive can be set up to perform perfectly even in complex applications. It is supported by guided programming of specific functions and the use of a PC software tool for parameterizing. And, thanks to its coated PCBs, the drive ensures reliable and cost-effective operation also in demanding environments.
Additional Information:
Product Details:
Brand | Danfoss |
Voltage | 380-480 V |
Current | 190-400 A |
Frequency | 50/60 Hz |
Power Source | Electric |
Application | Industrial |
The VLT® Advanced Active Filter AAF 006 improves system efficiency and increases grid robustness to avoid downtime. It can compensate for individual drives or it can be installed as a compact standalone solution at a point of common coupling to compensate for several loads simultaneously.
The active filter ensures optimal harmonic suppression independent of the number of loads and their individual load profile. In addition, it corrects the power factor and balances the phase load to provide optimal energy utilization.
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Danfoss |
Material | MS |
Usage/Application | Industrial |
Output Power | 0.75 kw to 630 kw |
Output Frequency | 0-3200 HZ |
Voltage | 380 - 440 V |
Product Details:
Phase | Single Phase |
Brand | VLT |
Weight | 20 kg |
Power | 0.18 kW to 1.4 MW |
Model | MCC 105 |
Power Source | Electric |
Product Details:
Material | DU/DT |
Model | MCC 102 |
Weight | 1500 kg |
Voltage | '200 - 690 V |
Current | Up to 880 A |
Frequency | 50 Hz |
Phase | Three Phase |
Product Details:
Brand | Danfoss |
Material | MS |
Voltage | 240 V |
Weight | 2 kg |
Color | White |
Frequency | 50 Hz |
Power Source | Electric |
Product Details:
Phase | Three Phase |
Voltage range | 200 - 500 V, 525 - 690 V |
Nominal Current | 2.5 - 800 A (500 V) 4.5 - 660 A (690 V) |
Ambient Temperature | -25 Degree to 45 DegreeC without derating |
Maximum Switching Frequency | 8 kHz |
Power Source | Electric |
Product Details:
Voltage | 220V,240V,690V, 1.1kV |
Phase | Three Phase |
Frequency | 50 Hz |
Model | MCC 103 |
Power Source | Electric |
Supply | MCC 103 line reactor series | ||||
200-240 V | |||||
Type code power rating (*1) | Max. input current (*2) | Ratings | Voltagedrop Uk | Ordering number | |
Current at 500 V | Inductance | ||||
[kW] | [A] | [A] | [mH] | [V] | [P/N] |
0.37 | 2.2 | 2.3 | 3.2 | 1.7% | 175U0296 |
0.55 | 3.2 | 2.7 | 2.6 | 2.0% | 175U0297 |
0.75 | 4.1 | 3.8 | 1.95 | 1.9% | 175U0298 |
1.1 | 5.9 | 5.3 | 1.4 | 2.0% | 175U0299 |
1.5 | 6.8 | 7,0 | 1.05 | 1.7% | 175U0300 |
2.2 | 9.5 | 9.1 | 0.808 | 1.8% | 175U0303 |
3,0 | 11.3 | 12.2 | 0.601 | 1.6% | 175U0306 |
3.7 | 15 | 15 | 0.49 | 1.7% | 175U0307 |
5.5 | 22 | 25 | 0.32 | 1.7% | 175U0308 |
7.5 | 28 | 32 | 0.23 | 1.5% | 175U0309 |
11 | 42 | 44 | 0.167 | 1.7% | 175U0311 |
15 | 54 | 60 | 0.123 | 1.6% | 175U0314 |
18.5 | 68 | 72 | 0.102 | 1.6% | 175U0315 |
22 | 80 | 89 | 0.083 | 1.6% | 175U0317 |
30 | 104 | 104 | 0.07 | 1.7% | 175U0318 |
37 | 130 | 145 | 0.051 | 1.6% | 175U0319 |
45 | 154 | 174 | 0.042 | 1.5% | 175U0321 |